Precision Universal Thermocouple and RTD Temperature
Calibrator provides
high accuracy calibration, measure and source thermocouples, RTDs, Ohms
and millivolts in one easy to calibrator |
|
|
|
The PTC-8001
Precision Temperature Calibrator is an
ideal device to handle all of your
temperature calibration needs in a
truly rugged, low-cost package. It
combines virtually all widely used
thermocouples and RTDs in one device,
you’ll never have to worry about
finding a temperature device you can’t
calibrate. This is especially true
when calibrating “smart” or pulsed RTD
transmitters, where many other
calibrators fail to work or operate at
reduced accuracy specs. The PTC-8001
handles those applications with ease. |
|
PTC8001
Calibrator Supplied with |

|
|
Protective Rubber Boot |

|
Features
•
Calibrate thermocouples and
RTDs with one unit
•
Works with Rosemount
3144 and all other smart
transmitters
• Direct
keyboard entry enables quick
output changes
•
High accuracy ±0.4°C J T/C and
±0.3 °C 4W PT385.RTD; all
errors included
•
Measure or Read Ten (10) T/C types and
eight (8) RTD types including
PT 385 (1,000 Ohm) and Cu (10
Ohm)
•
NEMA 4 rated case,
rugged design
•
RTD simulation works
with all pulsed (smart)
transmitters
•
YSI 400 series
thermistor range for
medical. applications
• Store up to nine (9)
setpoints for each output
function
• RTD function compatible with
all pulsed transmitters • RS232 interface
|
|
|
|
Specifications
Thermocouple Types:
J, K, T, E,
R, S, N, B, L, U including 10 to
70 mV range
Temperature scale:
ITS90
RTD
Types:
Pt 385
(100, 200, 500, 1000 ohms) Pt
392, JIS, Ni 120, CU10, YSI 400
Input Ranges: See Tables
below Accuracy: See Tables
below
Ohms Ranges:
0 to
400.00 and 400.0 to 3200.0
RTD
IEX-range:
0.01mA to 3mA RTD
Frequency Response:
10mS works with all pulsed
transmitters
Operating
Temperature:
-10°C to
50°C Storage
Temperature:
-40°C to
60°C Power Supply:
4 AA
Alkaline Cells, 30 hours typical
operating time
Size: 7.5" x
4" x 1.5"
|


|
|
PTC8001 LCD Display |
|
|
TC Type
|
Range °C (°F)
Read and Source
|
Accuracy*
|
|
J
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.6°C (1.1°F)
|
|
|
0 to 1200.0°C (32 to
2192°F)
|
0.4°C (0.7°F)
|
|
K
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.8°C (1.5°F)
|
|
|
0 to 1370°C (32 to
2498°F)
|
0.5°C (0.9°F)
|
|
T
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.8°C (1.4°F)
|
|
|
0 to 400.0°C (32 to
752°F)
|
0.5°C (0.9°F)
|
|
E
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.6°C (1.1°F)
|
|
|
0.0 to 950.0°C (32 to
1742°F)
|
0.4°C (0.7°F))
|
|
R/S
|
-20 to 0°C (-4 to 32°F)
|
2.8°C (4.3°F)
|
|
0 to 500°C (32 to 932°F)
|
1.7°C (3.1°F)
|
|
500 to 1775.0°C (932 to
3182°F)
|
1.4°C (2.5°F)
|
|
B
|
600.0 to 800.0°C (1112 to
1472°F)
|
2.1°C (3.8°F)
|
|
|
800.0 to 1000.0°C (1472
to 1832°F)
|
1.7°C (3.1°F)
|
|
|
1000.0 to 1800.0°C (1832
to 3272°F)
|
1.3°C (2.4°F)
|
|
L
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.45°C (0.81°F)
|
|
|
0 to 900.0°C (32 to
1652°F)
|
0.4°C (0.7°F)
|
|
U
|
-200.0 to 0.0°C (-328 to
32°F)
|
0.7°C (1.3°F)
|
|
|
0 to 400.0°C (32 to
752°F)
|
0.45°C (0.8°F)
|
|
N
|
-200.0 to 0.0°C (-328 to
32°F)
|
1.1°C (2.0°F)
|
|
|
0 to 1300.0°C (32 to
2370°F)
|
0.6°C (1.1°F)
|
|
mV
|
Source and Read
|
|
|
-10 to 75
|
0.015% +2
|
*All TC errors include CJC errors CJC error outside of 23 ± 5°C is
0.05°C/°C
|
RTD Type
|
Range
|
Accuracy*
|
|
Pt100 (385)
|
-200.0to 800.0°C (-328 to
1472°F)
|
0.33°C (0.6°F)
|
|
Pt200 (385)
|
-200.0 to 630.0°C (-328 to
1166°F)
|
0.8°C (1.4°F)
|
|
Pt500 (385)
|
-200.0 to 500.0°C (-328 to
932°F)
|
0.3°C (0.54°F)
|
|
|
500.0
to 630.0°C (932 to 1166°F)
|
0.4°C (0.72°F)
|
|
Pt1000 (385)
|
-200.0 to 100.0°C (-328 to
212°F)
|
0.3°C (0.5°F)
|
|
|
100.0
to 630.0°C (212 to 1166°F)
|
0.3°C (0.5°F)
|
|
Pt100 (3926)
|
-200.0 to 630.0°C (-328 to
1166°F)
|
0.3°C (0.5°F)
|
|
Pt100 (3916)
|
-200.0 to 630.0°C (-328 to
1166°F)
|
0.3°C (0.5°F)
|
|
Ni120 (672)
|
-80.0 to 260.0°C (-112 to 500°F)
|
0.2°C (0.4°F)
|
|
Cu10
|
-100.0 to 250.0°C (-148 to
482°F)
|
2.2°C (3.96°F)
|
|
Cu50
|
-180.0 to 200.0°C (-292 to
392°F)
|
0.5°C (0.9°F)
|
|
Cu100
|
-180.0 to 200.0°C (-292 to
392°F)
|
0.3°C (0.5°F)
|
|
YSI400
|
15.00
to 50.00 (59 to 122°F)
|
0.1°C (0.2°F)
|
|
Signal Type
|
Minimum Range
|
Maximum Range
|
Excitation Current
|
Accuracy
|
|
Ohms Read (low)
|
0.00
|
400.00
|
NA
|
0.1W
|
|
Ohms Read (high)
|
400.0
|
1500.0
|
NA
|
0.5W
|
|
|
1500.1
|
3200.0
|
NA
|
1.0
W
|
|
Ohms Source (low)
|
5.00
|
400.00
|
0.1 to 0.5mA
|
0.15
W
|
|
|
5.00
|
400.00
|
0.5 to 3mA
|
0.1
W
|
|
Ohms Source (high)
|
400.0
|
1500.0
|
0.05 to 0.8mA
|
0.5
W
|
|
|
1500.0
|
3200.0
|
0.05 to 0.4mA
|
1.0
W
|
|
|
Each
instrument includes
Instruction Manual, Protective
Rubber Boot and NIST Calibration
Certificate.
|
|
 |
|
|
|
|
|
Multifunction Temperature and Process Calibrators, Thermocouple and mA Calibrators, Thermocouple and RTD Dry Block Calibrators, Portable Infrared Thermometers, Fixed Mounted Industrial Infrared Thermometers, Thermocouple and RTD 2-wire Head Mounted Transmitters, DIN Rail Mounted Thermocouple and RTD Transmitters, Temperature and Process Panel Meters, Temperature & Humidity Transmitters, Hand Held Digital Thermocouple Thermometers, MIST Microprocessor Based Integral Transmitter RTD Temperature
Sensors,
Industrial Test tools and Maintenance Kit, Indoor Air
Quality (IAQ) and Test Meters, Hand Held Humidity and Air Flow Meters, Industrial Portable
Refrigerant and Gas Leak Detection Meters,
Pressure Measurement and Calibration Instruments
Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers
* NY * 10710 Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email: sales@tnp-instruments.com© 2006 - 2010 Temperature & Process Instruments, Inc.
|
|
|
 |